Lodestar CL4B

Fault Locator Lodestar CL4
Fault Locator Lodestar CL4
Fault Locator Lodestar CL4
Lodestar CL4 set
Description

INQUIRY NOW

Technical specifications

PARAMETER VALUE
Operating parameters
Operating voltage 6-35 kV
36-70 kV (option with Faraday cage)
Operating current 0-1000 A
Operating frequency 50/60 Hz
Conductor size 5-40 mm / 19,6-1256 mm²
Fault sensing
Type of faults PtP faults
PtG faults
Transient faults
Detection of earth fault direction Forward & Backward (Lodestar CL0.5B)*
Absolute threshold 20 A ... 1000 A
Differential thresholds 20 ? … 500 A / 50 % ... 500 %
Minimum fault sensing (PtG)
Zero sequence thresholds/3I0
0.5 – 100 A (Lodestar CL0.5B)
2 – 100 A (Lodestar CL2B)
4 – 100 A (Lodestar CL4B)
Response time 20 ms
Fault notification
Visual Ultra bright LED (white)
> 100 m – day time @sunny weather
> 500 m – night time
Resistance
Current withstand 25 kA /500 ms
In-rush resistance 0-200 ms /step 20 ms
Communication
Short-range communication technology Built-in BLE module, 50 m
On-site configuration and control Mobile App Lodestar (Android, iOS)
Long-distance communication Pole-mounted communication box (GSM)
Fault management software KOMORSAN
Reset
By timer 1 hour ... 8 days (configurable)
Remote Lodestar App, KOMORSAN
Reenergized line By voltage
Manual Magnet
Physical characteristics
Dimensions 140 x 114 x 158 mm
Weight 0.55 kg
Housing UV resistant polycarbonate
Ambient conditions
Temperature range -40 ... +75 °C
IP protection IP68
Salty fog Resistant (IEC 60068-2-11)
Installation
Installation tools Dielectric rod
Lodestar hotstick tool adaptor
Installation method Live line
Battery
Battery type and capacity Lithium, 19 Ah, 3.6 V
Battery life time >1000 h, >7 years
Low battery alarm At 20 % of remaining battery load
- visual by LED blinking (yellow color)
- KOMORSAN notification
Other
Applicable standards ANSI / IEEE 495
Internal memory 20 000 events
Measured telemetry parameters Currents (10-15% accuracy)
Voltage absence/presence

*Only for isolated neutral grounding. Min 5 km behind FPIs is required.

 

Lodestar CL4B was designed for fault detection with minimum load current 4A. This is a cost-effective and reliable solution for fixing an emergency process. Lodestar CL4B supports a range of communication options, including 3G or 4G LTE communications for a high speed data transfer. Lodestar CL4B devices operate independently of each other, transmitting information about the processes in each phase.

Lodestar CL4B benefits:

• Minimum fault sensing 4A;
• Identifies temporary and permanent faults;
• Registering and storing fault information such as timestamp, event type and measured values;
• Battery status control and indication.

 

Documentation is provided upon request to the company's clients. Please fill in the form to send a request:

+

By sending this form, I consent to the processing of my personal data.