Lodestar FM-CS2 | ATRIY
 +971 555-998-004

Lodestar FM-CS2

Lodestar FM

INQUIRY NOW

Technical characteristics of Lodestar FM-CS2

PARAMETER VALUE
 Types of logged faults - 2-and-3- phase short-circuit fault identification;
- 2-and-3- phase short-circuit fault direction finding;
- 2-and-3- phase-to-ground fault identification;
- 2-and-3- phase-to-ground fault direction finding;
- Phase-to-ground fault identification;
- Phase-to-ground fault direction finding.
 Recording the line switching faults Yes
 Selictivity Phase-to-ground and short-circuit faults direction finding (PtG, PtP)
 Determining the directions of PtG Yes
 Current response threshold PtG from 0,5 A
 Current response threshold PtP from 10 A
 External measuring sensor - Rogovsky coil (6 pcs.)
- Standard / capacitive divider
 Fault visual indication - LED-display;
- LED-indication
 Number of memorized faults  240
 Power supply used in the indicator - Inbuilt standby removable lithium storage battery (15 years);
- Powered via operation current source with any type of voltage =100 – 240 V (±10%),
 Fault indication reset - By an external command;
- By the timer;
- By the device button
 Interface RS-485 MODBUS communication protocol
Ethernet IEC104 communication protocol
 Logging of - Voltage;
- Current;
- Power;
- Industrial frequency;
- Power factor in three phases;
- Flow distribution direction
 Measurement accuracy - Voltage:
  - when using capacitive dividers - 3%;
  - when using voltage transformer - 1%;
- Current 3%;
- Active, reactive and full power - 3%;
- Industrial frequency - 1%
Temperature Range standard from -50 °C  to +70 °C

 

Minimum dimensions – maximum functionality.

A Feeder Monitor Lodestar FM-CS2 can be used as a logger, fault current indicator, high-voltage control device. It is designed for switchgear cell with double cable output.

Lodestar FM-CS2:

  • Detects fault direction
  • Effective in resonant grounded neutral grid
  • Logs all types of emergency situation:
    - phase-to-phase faults;
    - phase -to-ground faults;
    - 2-or-3-phase -to-ground faults
  • Operates in mixed networks: overhead, cable and overhead-cable ones
  • High accuracy in measurement of current and voltage
  • Up to 0.1 A short-circuit faults logging
  • Immediate data processing in the Device
  • Operates in double-ended and loop fed networks, as well as in radial networks
  • Feeder Monitor Lodestar FM-CS2 displays a faulted phase on the front LED-display
  • Event information both visually and in the SCADA system
  • Easy to configure by a couple of clocks in SW
  • Memorizes more than 200 events

Combines the functions of selective detection of all faulted lines and main power parameters measurement.

Feeder Monitor Lodestar FM-CS2 monitors independently each input of switchgear cell with double cable input The Device in mounted in a switchgear cell or on a switchboard.

 

Documentation is provided upon request to the company's clients. Please fill in the form to send a request:

+

By sending this form, I consent to the processing of my personal data.

Efficient and reliable operation of electrical networks demands accurate and real-time data collection. ATRIY’s advanced feeder monitors are designed specifically for substation installation, providing essential insights for precise operational control and swift detection of damaged sections in both overhead and underground line systems.

Comprehensive Monitoring Solutions

ATRIY's feeder monitors integrate seamlessly into existing SCADA systems, enhancing visibility and responsiveness across the grid. These robust monitoring solutions deliver continuous measurements of crucial electrical parameters such as current, voltage, frequency, and load status. As a result, network operators gain increased situational awareness, enabling proactive management and rapid response to potential faults.

Key advantages include:

  • Accurate and immediate detection of fault locations
  • Precise control of network parameters
  • Integration in advanced SCADA systems
  • Real-time monitoring for proactive decision-making

Key Features and Applications

ATRIY’s feeder monitors are particularly effective for high voltage applications, ensuring reliable operation and safety in challenging environments. Each device includes a highly sensitive sensor and an intuitive indicator system, offering clear visibility of the system status. This technology is essential for enhancing the performance and reliability of electrical distribution networks.

Main features:

  • Suitable for overhead and underground lines
  • Robust and reliable operation under extreme environmental conditions
  • High accuracy measurement of each phase parameters
  • User-friendly interfaces and simple integration

Benefits of ATRIY’s Feeder Monitors

Choosing ATRIY’s feeder monitors brings numerous operational benefits:

  • High reliability and reduced downtime due to early fault detection
  • Optimized network control reducing operational and maintenance costs
  • Enhanced grid stability through precise parameters monitoring
  • Improved decision-making capabilities with comprehensive real-time data

ATRIY’s monitoring device helps utilities significantly reduce operational risks and improve efficiency, ensuring stable and secure power distribution across the grid.

Invest in advanced feeder monitoring system today and experience superior network reliability and operational excellence.


Our customers
Contact Us

  Iris Bay 21st Floor, Office # 2105-2108, Business Bay, Dubai, UAE

 

  +971 555-998-004

Get Product Updates