Technical characteristics of Lodestar FM-FLx system
| PARAMETER |
Lodestar |
Lodestar |
Lodestar |
| Mains voltage level, kV | 230 | 6-36 | |
| Mains frequency, Hz | from 45 Hz to 65 | ||
| Recorded fault types | |||
| Identification of single-phase faults | + | ||
| Identification of two-phase and three-phase faults | + | ||
| Determination of two-phase and three-phase faults direction | + | ||
| Direction determination for phase-to-phase and three-phase faults involving ground | + | ||
| Identification of single-phase PtG | + | ||
| Determination of single-phase PtG direction | + | ||
| Selectivity | determination of short-circuit faults direction | determination of single-phase PtG, short-circuit faults direction | |
| Fault location determination |
with an accuracy of ±300 m KOMORSAN software implementing a fault location mechanism |
||
| Power supply | |||
| Supply from any of the following control voltages: |
|
||
| Fault indication reset |
|
||
| General description of devices | |||
| Visual fault indication |
|
||
| Minimum zero-sequence current for single-phase PtG registration, А | - | 0.5 | - |
| Fault detection during line switch-on | + | ||
| Number of latest faults stored in the internal memory | 240 | ||
| Communication |
|
||
| Operation monitoring |
|
||
| Changing settings |
|
||
| Integration with SCADA systems |
|
||
| Recording |
|
||
| Measurement accuracy |
|
|
|
| Mounting | switchboard panel | into a switchgear cell, on a control panel | |
| Connection |
|
|
|
| Operating temperature range, °С | from –40 to +70 | ||
| IP rating of the feeder monitor | IP 20 | ||
Now it is possible to detect simply the fault localization on overhead and cable power lines with the new universal device Lodestar FM-FL. Such ultra-compact device, mounted easily in the switchgear, monitors the network status constantly and determines the damage location with accuracy of 300 meters. Working in networks with any type of neutral, Lodestar FM-FL Fault Location System records any type of emergency situations on cable and overhead distribution line.
For switchgear that are not equipped with their own current sensors, it is recommended to install Lodestar FM-FL with current sensors based on the Rogowski coil, which is installed in substations where standard current transformers are not planned, mounted or required.
The intelligent feeder monitor analyzes a wide range of parameters and displays on-line the characteristics of current, power, voltage, etc., as well as minimum and maximum values of flow.
Lodestar FM-FL is available to order in three modifications depending on the voltage class and current sensors:
- Lodestar FM-FL+ voltage class 6-36 kV with Rogowski coils;
- Lodestar FM-FL voltage class 6-36 kV with current transformer sensors SCTххх;
- Lodestar FM-FL HV voltage class up to 230 kV with current transformer sensors SCTххх.
Benefits:
- Multiple configurations – wide range of versions for different network requirements.
- Continuous network monitoring – real‑time network status awareness.
- Geographic fault visualization – exact fault location displayed on a map.
- High‑accuracy fault location – determines fault location with ±300 m accuracy for long-distance lines.
- Comprehensive fault recording – records all types of faults.
- Flexible SCADA integration – supports IEC 60870‑5‑104 over Ethernet; Modbus over RS‑485.

Lodestar FM-CS2